Installation Of Pump and Valve Packings

Packing The Pump Correctly The importance of packing the pump correctly cannot be overemphasized. Many packing failures are due to incorrect installation of the packing. The following steps have been devised to ensure effective installation of packings on pumps: 1) REMOVE ALL THE OLD PACKING FROM THE STUFFING BOX. Clean box and shaft thoroughly and [...]

By |2017-03-08T19:57:48+00:00January 21st, 2011|Packing, Pump Repair, Pumps, Tech Tip|0 Comments

Troubleshooting Packing Failures

Packings may fail for a variety of reasons. Beside improper installation, packing failures are often due to worn or faulty equipment, shaft misalignment, uneven take-up on the gland bolts, and other causes. If you are having trouble, carefully remove and examine the old packing set. DO NOT THROW THE SET AWAY, because it often gives [...]

By |2013-01-31T22:20:55+00:00January 21st, 2011|Packing, Tech Tip|0 Comments

Use VFD To Save Energy Costs

When flow rate through a pump system is controlled by a discharge throttle valve, there is valuable energy going to waste. (It's like driving with your brakes on.) A Variable Frequency Drive (VFD) can harness that energy by matching pump speed to flow rate. To calculate the potential savings, measure the pressure drop across the [...]

By |2017-03-08T19:57:48+00:00November 2nd, 2010|Tech Tip|0 Comments